Clinical application and quantitative evaluation of generator-produced copper-62-PTSM as a brain perfusion tracer for PET
Copper-62-pyruvaldehyde bis(N4-methylthiosemicarbazone) copper II (62Cu-PTSM) has been proposed as a generator-produced positron-emitting tracer for perfusion imaging. To evaluate the characteristics of 62Cu-PTSM as a cerebral perfusion tracer, brain PET images of 62Cu-PTSM were compared with cerebral blood flow (CBF)
Article, 1994